Confirm coverage.
Check the site or route and the effects of metal containers, dense loads and mounting position.
HOW THERMOLOGIX WORKS
Follow a temperature reading from the monitoring point to your team.
NanoTag captures readings. LoRaWAN gateways carry received transmissions to the backend. ThermoCloud makes available data useful through graphs, configured notifications and reports.
Actual NanoTag artwork from the supplied brochure.EXPLORE THE DATA PATH
Select a stage to understand what happens there.
Install at a suitable agreed position near what you need to monitor. Tear-off activation starts the device. The published standard interval is ten minutes; confirm configuration options for the current revision.
UNDERSTAND THE CONNECTION
The device does not need a continuous connection to your phone. QR-code onboarding identifies the device in the app; the wireless network carries its readings to the backend.
Discuss network deployment ↗Check the site or route and the effects of metal containers, dense loads and mounting position.
A ten-minute default interval is not continuous second-by-second measurement. Agree the frequency your application requires.
Backup memory is documented. Confirm sample retention and recovery or forwarding behaviour for the chosen revision; automated backfill is not established by the supplied specifications.
FROM INSTALLATION TO EVERYDAY USE
Agree the location, attach using the specified mounting method and activate the device. Verify what the local reading represents.
Add the device, set suitable limits, give users appropriate access and check notification delivery.
Check reading freshness, review trends and use available records alongside the organisation’s procedures.
PRACTICAL CUSTOMER QUESTIONS
At a suitable point selected for the decision you need to support. A local sensor reading does not describe every shelf or automatically measure a product’s core temperature. Use qualified mapping or placement assessment where required.
Fresh readings and notifications may stop reaching the platform. NanoTag includes backup memory, but retention and later recovery must be confirmed for the device revision. Use an agreed contingency rather than treating a data gap as normal conditions.
ThermoCloud documentation describes user-set limits and notification preferences. Agree thresholds, recipients and a response process, then test delivery using the actual setup.
The material describes multiple-device management and multi-user access. Confirm practical capacity, account structure and any subscription limits with Thermologix.
The organisation’s designated team investigates the conditions and follows its approved product and quality procedures. A return to normal temperature does not by itself determine whether affected stock is suitable.
Automatic cooling or HVAC control is not documented. NanoTag measures temperature; the platform provides monitoring information and configured notifications.
LET’S MAKE THE SYSTEM FIT
Discuss device suitability, placement, coverage, reporting and the people who will use the information.